How To Install Electric Heating Floor
Determine the circuit requirements.
How to install electric heating floor. Use hot melt glue to secure the thermostat wires to the floor and the power lead in the groove. The casing is normally mounted along the wall above the floor and the heater pipe is installed inside a few inches above the floor level. Some floor heat systems are available in specific sized heat mats or a custom mat may be made for the specific design and shape of a custom floor such as a bathroom. The heating cable must be gfci protected.
Types of electric heated floors. Cover the notches in the bottom plate with protective metal plates. Radiant heating works well with ceramic tile and vinyl but not with wood floors. Hot melt glue the power lead into the groove.
You should read and follow all manufacturer s installation instructions and guidelines though. With a hydronic system you can attach aluminum plates beneath the floor to spread and store heat. You have to position the cable in a serpentine pattern fasten it with lots of hot glue or staples and then embed it. Install conduit connectors to both ends of two pieces of 58 in.
You can install the heating elements right against the floor. Laying out the area for the floor heat system the area of where the floor is to be heated needs top be identified and measured. Fish the power lead cable through one length of conduit. This video shows step by step on how to install your electric underfloor heating.
Most electric radiant floors involve laying strips of electrical matting across the subfloor linked together and connected to an electrical circuit and line voltage thermostat and secured in place by a covering of thin set mortar. For this type of electric heated flooring the cable comes on a spool just like any other wire. Electrical metal tubing emt that are long enough to run from the floor to the electrical box for the thermostat. The basic process for installing a electric floor heating system.
In most cases you ll need to run a new circuit on a 15 or 20 amp breaker. Electrical metal tubing emt. Install the circuit then install the thermostat that turns on the heated floor. Install conduit connectors to both ends of two pieces of 1 2 in.
The drawback of loose cable is installation time. In an existing home installation is usually below the floor as long as the area beneath the floor is accessible. The heat shield casing keeps the heat adequately away from the carpeting. Loose cable is by far the cheapest way to heat a floor and it s just as effective as the other systems.
Its success with carpeted floors depends on the length of the weave thick carpets or those with thick pads won t work well as.